25122--Tolleson-Park-Aquatics-Center-002-PCCO-#002-July-2026_CroySigned
Open official source ↗ · Source page 33
GFCI GFCIGFCI FLOW IF THE HEATER IS U SIN G A DEDIC ATED AIR IN TAKE, A R EAR OR SIDE OPT ION MU ST BE SELECT ED. TH ESE WILL EXPAN D T HE FOO TPR INT OF TH E H EATER . IF T HE HEATER S ARE STACKED, THE T OP HEATER MUST USE T HE REAR CON NEC TION WHILE TH E LOWER C AN USE EITHER. AIR IN TAKES TO BE CO ORD INATED W ITH TH E MECH AN ICAL ENGINEER AND CO NSIDER ED WIT HIN TH E MECH ANICAL R OOM FO OTPRIN T. REAR SID E 6 5 5 4 2 1. 5 6 5 SUCT ION WASTE R ETUR N SUCT ION WASTE R ETUR N SUCT ION WASTE R ETUR N 6 5 6 5 6 5 TO POOL FROM PUMP BACKWASH 6 5 TO POOL FROM PUMPBACKWASH PP1 PP2 PP3 PP4 PP5 PP6 PP7 1A 1B 2B 3B CF6 F3 F3 F3 F1 F2 1C 2C 2C 2C 3C 3C 4A 5A 5C 5B 5F H1 L1 L2 L3 1E3E 3D 2D 1D 2E 2A 3A CF5 CF4 5D CF1 CF2 CF3 U1 U1 LAZY RIVER DRIVE LAZY RIVER DRIVE SPRAY PAD RECIRCULATION SPRAY PAD FEATURES LEISURE POOL RECIRCULATION LAP POOL RECIRCULATION ACID ROOM - pH CONTROL CHLORINE ROOM BACKWASH PIT SPRAY PAD FILTRATION SYSTEM LEISURE & RIVER FILTRATION SYSTEM - STACKED FILTERS LAP POOL FILTRATION SYSTEM - STACKED FILTERS LAP POOL CHEMICAL CONTROLLER LEISURE POOL CHEMICAL CONTROLLER SPRAY PAD CHEMICAL CONTROLLER WATER LEVEL CONTROLLERS POOL PUMP VFD'S 43'-0" X 12'-0" X 5'-0" DEEP PUMP PIT WATERSLIDE 10'-0" 10'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 10'-0" 10'-0" 9'-0" 9'-0" 8'-0" 8'-0" 9'-0" 8'-0" 8'-0" 7'-6" 7'-6" 9'-0" 9'-0" 9'-0" 744.88 SF ASSEMBLY 1 50 631.93 SF BUSINESS 1 5 88.31 SF HAZARD H2 1 1581.53 SF UTILITY 4 172.51 SF STORAGE 1 1 819.11 SF BUSINESS 2 6 OCCUPANCY TYPES (NFPA101) ACCESORY STORAGE AREAS MECHANICAL EQUIPMENT ROOM (NFPA101) ASSEMBLY - NO FIXED SEATS - UNCONCENTRATED (NFPA101) BUSINESS AREAS (NFPA101) HIGH HAZARD GROUP H2 (NFPA101) UTILITY 17'-6"TD 33'-5" TD 44'-1" TD 64'-7" TD 51'-3" TD NOTE: DELEGATED DESIGN OF FIRE SUPPRESSION SYSTEM SHALL INCLUDE AESTHETIC UPGRADES IN THE DESIGN SOLUTION FOR VISUALLY SENSITIVE SPACES OVER TRADITIONAL UTILITARIAN SYSTEM DESIGN SOLUTIONS. THESE SPACES INCLUDE THE OUTDOOR PATIO SPACE, MULTIPURPOSE ROOM, ADMISSIONS OFFICE, BREEZEWAY SPACE, MEN AND WOMEN LOCKER ROOMS AND LIFEGUARD BREAK SPACE. FIRE SUPPRESSION ENGINEER SHALL CONCEAL WHERE POSSIBLE SPRINKLER SYSTEM COMPONENTS, SPRINKLER MAINS, BRANCHES AND HEADS SHALL BE CENTERED AND ALIGNED IN THE ABOVE SPACES TYPICALLY, EXPOSED COMPONENTS SHALL BE OF COMPATIBLE EXPOSED FINISHES FOR SUCH APPLICATIONS. FIRE SUPPRESSION DESIGNER SHALL SUBMIT FOR AESTHETIC APPROVAL OF THE ARCHITECT IN ADDITION TO PERFORMANCE REQUIREMENTS AND ALLOW FOR UP TO TWO DESIGN REVISIONS AND MEETINGS WITH THE ARCHITECT TO EVALUATE SYSTEM AESTHETIC DESIGN SOLUTIONS. FE FE FE FE FEFE 26'-6" TD 18'-1"CP MULTIPURPOSE 105 MEP 103 STORAGE 106 PANTRY 104 CONCESSIONS 102 ADMIN 101 IT 111 JAN 110 RR 109 RR 108 CORRIDOR 107 JAN 113 MEN'S LOCKER RM 114 WOMEN'S LOCKER RM 117 OFFICE 120 OFFICE 118 LIFEGUARD BREAK 119 POOL EQUIPMENT 121 PIT ROOM 123 SPRINKLER RISER ROOM 131 ELEC. CLOSET 125 CHEMICALS 122 FAM RR 116 MOTHER 115 ROOF ACCESS 132 CLOSET 120A 812.61 SF OUTDOOR PATIO 000 90 90 90 90 90 90 16'-5" TD 3' - 4" FACP AED AED 90 2' - 0" CONTRACTOR SHALL PROVIDE RECESSED FIRE DEPARTMENT KEY ACCESS CONTROL BOX, B.O.D. KNOX MODEL #3200, FINISH TO BE SELECTED BY ARCHITECT FROM MANF. STANDARD FINISH SELECTION. MOUNT AT CENTER OF BOX AT 48" AFF 3 TURNSTILE WITH EMERGENCY BREAKAWY ARMS FOR EGRESS 3 FUTURE EXPANSION 19'-9"TD RETRACTABLE BARRIER NETTING RETRACTABLE BARRIER NETTING RESTROOM 127 RESTROOM 128 389.11 SF OUTDOOR PATIO 126 LIFE SAFETY LEGEND EXIT TRAVEL DISTANCE COMMON PATH (PART OF TD) CP: 100'-0" TOTAL TRAVEL DISTANCE TD: 100'-0" DEAD END LENGTH DE: 100'-0" EXIT SIGN FE FIRE EXTINGUISHER; SURFACE MOUNTED CABINET SYMBOLS: OCCUPANT LOAD EXIT CAPACITY FIRE RATING OF OPENING 0 0 20 ROOM 101 ROOM NAME ROOM NUMBER WALL RATING: SMOKE PARTITION ONE-HOUR RATED FIRE PARTITION TWO-HOUR RATED FIRE BARRIER THREE-HOUR RATED FIRE BARRIER AED AED; SURFACE MOUNTED CABINET BUILDING: 2018 INTERNATIONAL BUILDING CODE W/ 2020 GEORGIA AMENDMENTS PLUMBING: 2018 INTERNATIONAL PLUMBING CODE W/ 2020 GEORGIA AMENDMENTS MECHANICAL: 2018 INTERNATIONAL MECHANICAL CODE W/ 2020 GEORGIA AMENDMENTS FIRE: 2018 INTERNATIONAL FIRE CODE W/ NO GEORGIA AMENDMENTS GAS: 2018 INTERNATIONAL FUEL GAS CODE W/ 2020 GEORGIA AMENDMENTS ENERGY: 2015 INTERNATIONAL ENERGY CONSERVATION CODE W/ 2020 GEORGIA AMENDMENTS ELECTRICAL: 2020 NATIONAL ELECTRICAL CODE W/ NO GEORGIA AMENDMENTS POOL: 2018 INTERNATIONAL SWIMMING POOL & SPA CODE W/ GEORGIA AMENDMENTS LIFE SAFETY: 2024 NFPA 101 LIFE SAFETY CODE, GEORGIA CHAPTER 120-3-3 ACCESSIBILITY: 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN CODES AND STANDARDS OCCUPANCY CLASSIFICATION (LSC - CHAPTER 7; IBC - CHAPTER 3): - LSC: ASSEMBLY / IBC: A-2 - LSC: BUSINESS / IBC: BUSINESS - LSC: STORAGE / IBC: S-1 - IBC: UTILITY - IBC: H2 (HAZARD) PRIMARY OCCUPANCY: BUSINESS TYPE OF CONSTRUCTION (IBC): VB NON-SEPARATED MIXED OCCUPANCIES (IBC 508.3.1) SPRINKLERED (NFPA 13R SYSTEM) AT MAIN AQUATICS BUILDING NOT SPRINKLERED AT RESTROOM BUILDING NOT SPRINKLERED AT RECREATION LOUNGE BUILDING SEE LIGHTING PLAN E01.04 FOR LOCATION OF EMERGENCY LIGHTS AND EXIT SIGNS. OCCUPANCY CLASSIFICATION AND CONSTRUCTION TYPE COMMON PATH: - ASSEMBLY = 20 FT / 75 FT - BUSINESS = 100 FT - STORAGE = 100 FT MEANS OF EGRESS: LSC CHAPTER 7, LSC TABLE A.7.6. PLUMBING FIXTURE COUNTS - IPC CHAPTER 4, ISPSC CHAPTER 6 WATER CLOSETS LAVATORIES DRINKING FOUNTAINS OTHER MALE 1 FEMALE MALE FEMALE 1 1 SERVICE SINK 1 1 1 ASSEMBLY OCCUPANTS: 50 (MULTIPURPOSE) + 55 (OUTDOOR PATIO SPACE) TOTAL: 105 (MALE = 52.5, FEMALE = 52.5) WATER CLOSETS LAVATORIES OTHER MALE 1 FEMALE MALE FEMALE 1 1 SERVICE SINK 1 1 1 BUSINESS OCCUPANTS: 11 WATER CLOSETS LAVATORIES OTHER MALE 3 FEMALE MALE FEMALE 2 2 SERVICE SINK SHOWERS: 2 MALE, 2 FEMALE5 4 4 TOTAL FIXTURES REQUIRED WATER CLOSETS: MALE - 1 PER 75; FEMALE - 1 PER 75 (FOOTNOTE: The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required.) LAVATORIES: 1 PER 200, BOTH MALE AND FEMALE DRINKING FOUNTAINS: 1 PER 500 OTHER: 1 SERVICE SINK FIXTURES PROVIDED 10 9 2 2 SERVICE SINK SHOWERS: 2 MALE, 2 FEMALE 3 URINALS PROVIDED WATER CLOSETS: 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50, BOTH MALE AND FEMALE LAVATORIES: 1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80, BOTH MALE AND FEMALE DRINKING FOUNTAINS: 1 PER 100 OTHER: 1 SERVICE SINK MAIN BUILDING, RECREATION LOUNGE AND POOL (WATER) AREAS:DEAD END: - ASSEMBLY = 20 FT - BUSINESS = 50 FT - STORAGE = 100 FT TRAVEL DISTANCE: - ASSEMBLY = 250 FT - BUSINESS = 300 FT - STORAGE = 400 FT FIRE RESISTANCE RATINGS: IBC CHAPTER 6, TABLE 601 PRIMARY STRUCTURAL FRAME= 0 HR BEARING WALLS - EXTERIOR= 0 HR BEARING WALLS - INTERIOR= 0 HR NONBEARING WALLS AND PARTITIONS, EXTERIOR= 0 HR NONBEARING WALLS AND PARTITIONS, INTERIOR= 0 HR FLOOR CONSTRUCTION= 0 HR ROOF CONSTRUCTION= 0 HR FIRE PROTECTION SYSTEMS - IBC CHAPTER 9 FIRE EXSTINGUISHERS FOR CLASS A (TABLE 906.3(1) ORDINARY HAZARD OCCUPANCY MINIMUM RATED SINGLE EXTINGUISHER 2-A MAXIMUM FLOOR AREA PER UNIT OF A 3,000 SF MAXIMUM FLOOR AREA FOR EXTINGUISHER 11,250 SF MAXIMUM DISTANCE OF TRAVEL 75 FT FIRE RATINGS & SEPARATION DISTANCE: IBC TABLE 602 FIRE SEPARATION DISTANCE RATING X < 5 1 HR 5 <= X < 10 1 HR 10 <= X < 30 0 HR X >= 30 0 HR MAX. AREA OF EXTERIOR WALL OPENINGS: IBC TABLE 705.8 FIRE SEPARATION DISTANCE RATING ALLOWABLE AREA 30 OR GREATER: UNPROTECTED, NONSPRINKLERED (UP, NS) NO LIMIT UNPROTECTED, SPRINKLERED (UP, S) NO LIMIT PROTECTED (P) NO LIMIT MAIN BUILDING: BUSINESS, MOST RESTRICTIVE RESTROOM BUILDING: BUSINESS, MOST RESTRICTIVE REC LOUNGE: BUSINESS, MOST RESTRICTIVE 1 1 3 6 4 4 ALLOWABLE BUILDING HEIGHT ABOVE GRADE (IBC TABLE 504.3) = 40 FT TOTAL BUILDING HEIGHT= 29'-4" ALLOWABLE NUMBER OF STORIES ABOVE GRADE, MOST RESTRICTIVE (IBC TABLE 504.4) = 2 STORIES STORIES ABOVE GRADE PLANE = 1 STORY ALLOWABLE AREA, MOST RESTRICTIVE (IBC TABLE 506.2) = 18,000 SF BUILDING: ALLOWABLE: ACTUAL: MAIN BUILDING: 9,000 GSF 7,807 GSF (NEW CONSTRUCTION) RESTROOM BUILDING 9,000 GSF 296 GSF (NEW CONSTRUCTION) BUILDING HEIGHTS & AREAS - IBC CHAPTER 5 POOL AREAS WATER CLOSETS LAVATORIES SHOWERS MALE 1 FEMALE MALE FEMALE N/A MALE: 2 FEMALE: 2 3 2 AREA (SF), OCCUPANTS: LAP POOL: 4654 SF, 94 OCC LEISURE POOL : 4314 SF, 87 OCC SPLASH PAD: 1406 SF, 29 OCC TOTAL: 8968 SF, 210 OCC 2 PER ISPSC 2018, FOR POOL AREAS ABOVE 7500 SF, FOR EVERY 7500 SF: WATER CLOSETS: 0.7 X MALE, 2 X FEMALE URINALS: 1 X MALE LAVATORIES: 0.85 X MALE, 1 X FEMALE SHOWER: 1 X MALE, 1 X FEMALE DRINKING FOUNTAINS DRINKING FOUNTAINS DRINKING FOUNTAINS WATER CLOSETS LAVATORIES OTHER MALE 1 FEMALE MALE FEMALE 1 1 1 1 ASSEMBLY OCCUPANTS: 26 (OUTDOOR PATIO) RESTROOM BUILDING: DRINKING FOUNTAINS WATER CLOSETS LAVATORIES OTHER MALE 1 FEMALE MALE FEMALE 1 1 1 1 TOTAL FIXTURES REQUIRED FIXTURES PROVIDED 2 2 2 1 1 1 1 DRINKING FOUNTAINS URINALS MALE 2 FEMALE N/A N/A N/A N/A WATER CLOSETS: MALE - 1 PER 75; FEMALE - 1 PER 75 (FOOTNOTE: The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required.) LAVATORIES: 1 PER 200, BOTH MALE AND FEMALE DRINKING FOUNTAINS: 1 PER 500 OTHER: 1 SERVICE SINK 3 RECREATION LOUNGE 127 77.60 SF BUSINESS 1 17'-5" DE PROJECT NORTH TRUE NORTH RELEASED FOR CONSTRUCTION THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M CYK Proj #: Reviewed By: 11/24/2025 5:05:24 PM Autodesk Docs://Smyrna AquaticsGymFamilyLearningLibrary/Smyrna Aquatics Gym Family Learning Library.rvt . G00.20 LIFE SAFETY PLAN 22.0001924.000 PROJECT ADDRESS: 3530 KINGS SPRINGS RD SE SMYRNA, GA 30080 TOLLESON PARK AQUATICS CENTER . CIVIL 200 COBB PARKWAY NORTH STRUCTURAL 3411 PIERCE DRIVE MEP 5064 ROSWELL ROAD CROY ENGINEERING, LLC. SHEAR STRUCTURAL SAVANT ENGINEERING, LLC. MARIETTA, GA 30062 CHAMBLEE, GA 30341 SANDY SPRINGS, GA 30342 770.971.5407 678.664.8051 770.319.7400 FOOD SERVICES 3103 MEDLOCK BRIDGE CAMACHO NORCROSS, GA 30071 770.246.2751 5200 Avalon Boulevard Alpharetta, GA 30009 WWW.NELSONWORLDWIDE.COM Phone: (770) 209-9393 Nelco Architecture, Inc. 1/8" = 1'-0"G00.20 1 MAIN BUILDING - CODE COMPLIANCE PLAN LIFE SAFETY- OCCUPANCY- LEVEL 1 MAIN BUILDING (NFPA101) ACCESORY STORAGE AREAS MECHANICAL EQUIPMENT ROOM 172.51 SF 300.00 SF 1 (NFPA101) ASSEMBLY - NO FIXED SEATS - UNCONCENTRATED 744.88 SF 15.00 SF 50 (NFPA101) BUSINESS AREAS 1451.03 SF 150.00 SF 11 (NFPA101) HIGH HAZARD GROUP H2 88.31 SF 500.00 SF 1 (NFPA101) UTILITY 1581.53 SF 500.00 SF 4 RECREATION LOUNGE (IBC2018) BUSINESS AREAS 77.60 SF 150.00 SF 1 4115.87 SF 68 1/8" = 1'-0"G00.20 3 RESTROOM BUILDING - CODE COMPLIANCE PLAN 1/8" = 1'-0"G00.20 2 REC LOUNGE - CODE COMPLIANCE PLAN 1 1 Issue: No: Date: DESIGN DEVELOPMENT 08-13-2025 PERMIT SET 09-30-2025 ISSUED FOR BID 1 10-16-2025 ADDENDUM #1 2 10-24-2025 PERMIT COMMENTS & CLARIFICATIONS 3 11-21-2025 2 . . . . RFI 28 RFI 28