GovernSmyrna.

25122--Tolleson-Park-Aquatics-Center-002-PCCO-#002-July-2026_CroySigned

Open official source ↗ · Source page 33

SHA-256 c31c4bee4f5ca172e0868b403f9bd2686b51a3f87b36bd2bec0f2ad0838008cc · Captured source extract

GFCI
GFCIGFCI
FLOW
IF THE HEATER IS U SIN G A DEDIC ATED AIR IN TAKE, A R EAR  OR  SIDE OPT ION  MU ST BE
SELECT ED. TH ESE WILL EXPAN D T HE FOO TPR INT  OF  TH E H EATER . IF T HE HEATER S ARE
STACKED, THE T OP HEATER  MUST  USE T HE REAR CON NEC TION WHILE TH E LOWER C AN
USE EITHER.
AIR  IN TAKES TO BE CO ORD INATED  W ITH  TH E MECH AN ICAL ENGINEER AND  CO NSIDER ED
WIT HIN  TH E MECH ANICAL R OOM FO OTPRIN T.
REAR
SID E
6
5
5
4
2
1. 5
6
5
SUCT ION
WASTE
R ETUR N
SUCT ION
WASTE
R ETUR N
SUCT ION
WASTE
R ETUR N
6
5
6
5
6
5
TO POOL
FROM
PUMP BACKWASH
6
5
TO POOL
FROM
PUMPBACKWASH
PP1 PP2 PP3 PP4
PP5 PP6
PP7
1A
1B 2B 3B
CF6
F3 F3 F3
F1
F2
1C 2C 2C 2C 3C 3C 4A
5A
5C 5B
5F
H1
L1
L2 L3
1E3E
3D
2D
1D
2E
2A 3A
CF5
CF4
5D
CF1
CF2
CF3
U1
U1
LAZY RIVER DRIVE
LAZY RIVER DRIVE
SPRAY PAD RECIRCULATION
SPRAY PAD FEATURES
LEISURE POOL RECIRCULATION
LAP  POOL RECIRCULATION
ACID ROOM - pH CONTROL
CHLORINE ROOM
BACKWASH PIT
SPRAY PAD FILTRATION SYSTEM
LEISURE & RIVER FILTRATION SYSTEM - STACKED FILTERS
LAP POOL FILTRATION SYSTEM - STACKED FILTERS
LAP POOL CHEMICAL CONTROLLER
LEISURE POOL CHEMICAL CONTROLLER
SPRAY PAD CHEMICAL CONTROLLER
WATER LEVEL CONTROLLERS
POOL PUMP VFD'S
43'-0" X 12'-0" X 5'-0" DEEP PUMP PIT
WATERSLIDE
10'-0"
10'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
10'-0"
10'-0"
9'-0"
9'-0"
8'-0"
8'-0"
9'-0"
8'-0"
8'-0"
7'-6"
7'-6"
9'-0"
9'-0"
9'-0"
744.88 SF
ASSEMBLY 1
50
631.93 SF
BUSINESS 1
5
88.31 SF
HAZARD H2
1
1581.53 SF
UTILITY
4 172.51 SF
STORAGE 1
1
819.11 SF
BUSINESS 2
6
OCCUPANCY TYPES
(NFPA101) ACCESORY STORAGE AREAS MECHANICAL EQUIPMENT ROOM
(NFPA101) ASSEMBLY - NO FIXED SEATS - UNCONCENTRATED
(NFPA101) BUSINESS AREAS
(NFPA101) HIGH HAZARD GROUP H2
(NFPA101) UTILITY
17'-6"TD
33'-5" TD
44'-1" TD
64'-7" TD
51'-3" TD
NOTE: DELEGATED DESIGN OF FIRE SUPPRESSION SYSTEM SHALL INCLUDE AESTHETIC UPGRADES IN THE DESIGN SOLUTION FOR VISUALLY SENSITIVE SPACES OVER TRADITIONAL UTILITARIAN SYSTEM DESIGN SOLUTIONS. THESE SPACES INCLUDE THE OUTDOOR PATIO SPACE, MULTIPURPOSE ROOM, ADMISSIONS OFFICE, 
BREEZEWAY SPACE, MEN AND WOMEN LOCKER ROOMS AND LIFEGUARD BREAK SPACE. FIRE SUPPRESSION ENGINEER SHALL CONCEAL WHERE POSSIBLE SPRINKLER SYSTEM COMPONENTS, SPRINKLER MAINS, BRANCHES AND HEADS SHALL BE CENTERED AND ALIGNED IN THE ABOVE SPACES TYPICALLY, EXPOSED COMPONENTS 
SHALL BE OF COMPATIBLE EXPOSED FINISHES FOR SUCH APPLICATIONS. FIRE SUPPRESSION DESIGNER SHALL SUBMIT FOR AESTHETIC APPROVAL OF THE ARCHITECT IN ADDITION TO PERFORMANCE REQUIREMENTS AND ALLOW FOR UP TO TWO DESIGN REVISIONS AND MEETINGS WITH THE ARCHITECT TO EVALUATE SYSTEM 
AESTHETIC DESIGN SOLUTIONS.
FE
FE
FE
FE
FEFE
26'-6" TD
18'-1"CP
MULTIPURPOSE
105
MEP
103
STORAGE
106
PANTRY
104
CONCESSIONS
102
ADMIN
101 IT
111
JAN
110 RR
109
RR
108
CORRIDOR
107
JAN
113
MEN'S LOCKER RM
114
WOMEN'S LOCKER
RM
117
OFFICE
120
OFFICE
118
LIFEGUARD
BREAK
119
POOL EQUIPMENT
121
PIT ROOM
123
SPRINKLER RISER
ROOM
131
ELEC. CLOSET
125
CHEMICALS
122
FAM RR
116
MOTHER
115
ROOF ACCESS
132
CLOSET
120A
812.61 SF
OUTDOOR PATIO
000
90
90 90 90 90
90
16'-5" TD
3' - 4"
FACP
AED
AED
90
2' - 0"
CONTRACTOR SHALL PROVIDE RECESSED FIRE 
DEPARTMENT KEY ACCESS CONTROL BOX, B.O.D. 
KNOX MODEL #3200, FINISH TO BE SELECTED BY 
ARCHITECT FROM MANF. STANDARD FINISH 
SELECTION. MOUNT AT CENTER OF BOX AT 48" AFF
3
TURNSTILE WITH EMERGENCY 
BREAKAWY ARMS FOR EGRESS
3
FUTURE 
EXPANSION
19'-9"TD
RETRACTABLE 
BARRIER NETTING
RETRACTABLE 
BARRIER NETTING
RESTROOM
127
RESTROOM
128
389.11 SF
OUTDOOR PATIO
126
LIFE SAFETY LEGEND
EXIT TRAVEL DISTANCE
COMMON PATH (PART OF TD)
CP: 100'-0"
TOTAL TRAVEL DISTANCE
TD: 100'-0"
DEAD END LENGTH
DE: 100'-0"
EXIT SIGN
FE FIRE EXTINGUISHER;
SURFACE MOUNTED CABINET
SYMBOLS:
OCCUPANT LOAD
EXIT CAPACITY
FIRE RATING OF OPENING
0 0
20
ROOM
101
ROOM NAME
ROOM NUMBER
WALL RATING:
SMOKE PARTITION
ONE-HOUR RATED FIRE PARTITION
TWO-HOUR RATED FIRE BARRIER
THREE-HOUR RATED FIRE BARRIER
AED AED; SURFACE MOUNTED CABINET
BUILDING: 2018 INTERNATIONAL BUILDING CODE W/ 2020 GEORGIA AMENDMENTS
PLUMBING: 2018 INTERNATIONAL PLUMBING CODE W/ 2020 GEORGIA AMENDMENTS
MECHANICAL: 2018 INTERNATIONAL MECHANICAL CODE W/ 2020 GEORGIA AMENDMENTS
FIRE: 2018 INTERNATIONAL FIRE CODE W/ NO GEORGIA AMENDMENTS
GAS: 2018 INTERNATIONAL FUEL GAS CODE W/ 2020 GEORGIA AMENDMENTS
ENERGY: 2015 INTERNATIONAL ENERGY CONSERVATION CODE W/ 2020 GEORGIA AMENDMENTS
ELECTRICAL: 2020 NATIONAL ELECTRICAL CODE W/ NO GEORGIA AMENDMENTS
POOL: 2018 INTERNATIONAL SWIMMING POOL & SPA CODE W/ GEORGIA AMENDMENTS
LIFE SAFETY: 2024 NFPA 101 LIFE SAFETY CODE, GEORGIA CHAPTER 120-3-3
ACCESSIBILITY: 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
CODES AND STANDARDS
OCCUPANCY CLASSIFICATION (LSC - CHAPTER 7; IBC - CHAPTER 3):
- LSC: ASSEMBLY / IBC: A-2
- LSC: BUSINESS / IBC: BUSINESS
- LSC: STORAGE / IBC: S-1
- IBC: UTILITY
- IBC: H2 (HAZARD)
PRIMARY OCCUPANCY:
BUSINESS
TYPE OF CONSTRUCTION (IBC): VB
NON-SEPARATED MIXED OCCUPANCIES (IBC 508.3.1)
SPRINKLERED (NFPA 13R SYSTEM) AT MAIN AQUATICS BUILDING
NOT SPRINKLERED AT RESTROOM BUILDING
NOT SPRINKLERED AT RECREATION LOUNGE BUILDING
SEE LIGHTING PLAN E01.04 FOR LOCATION OF EMERGENCY LIGHTS AND EXIT SIGNS.
OCCUPANCY CLASSIFICATION AND CONSTRUCTION TYPE
COMMON PATH:
- ASSEMBLY = 20 FT / 75 FT
- BUSINESS = 100 FT
- STORAGE = 100 FT
MEANS OF EGRESS: LSC CHAPTER 7, LSC TABLE A.7.6. PLUMBING FIXTURE COUNTS - IPC CHAPTER 4, ISPSC CHAPTER 6
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS OTHER
MALE
1
FEMALE MALE FEMALE
1 1 SERVICE SINK
1 1 1
ASSEMBLY
OCCUPANTS: 50 (MULTIPURPOSE) + 55 (OUTDOOR PATIO SPACE)
TOTAL: 105 (MALE = 52.5, FEMALE = 52.5)
WATER CLOSETS LAVATORIES OTHER
MALE
1
FEMALE MALE FEMALE
1 1 SERVICE SINK
1 1 1
BUSINESS
OCCUPANTS: 11
WATER CLOSETS LAVATORIES OTHER
MALE
3
FEMALE MALE FEMALE
2 2 SERVICE SINK
SHOWERS: 2 MALE, 2 FEMALE5 4 4
TOTAL FIXTURES REQUIRED
WATER CLOSETS: MALE - 1 PER 75; FEMALE - 1 PER 75 (FOOTNOTE: The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required.)
LAVATORIES: 1 PER 200, BOTH MALE AND FEMALE
DRINKING FOUNTAINS: 1 PER 500
OTHER: 1 SERVICE SINK
FIXTURES PROVIDED
10 9
2
2 SERVICE SINK
SHOWERS:  2 MALE, 2 FEMALE
3 URINALS PROVIDED
WATER CLOSETS: 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50, BOTH MALE AND FEMALE
LAVATORIES: 1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80, BOTH MALE AND FEMALE
DRINKING FOUNTAINS: 1 PER 100
OTHER: 1 SERVICE SINK
MAIN BUILDING, RECREATION LOUNGE AND POOL (WATER) AREAS:DEAD END:
- ASSEMBLY = 20 FT
- BUSINESS = 50 FT
- STORAGE = 100 FT
TRAVEL DISTANCE:
- ASSEMBLY = 250 FT
- BUSINESS = 300 FT
- STORAGE = 400 FT
FIRE RESISTANCE RATINGS: IBC CHAPTER 6, TABLE 601
PRIMARY STRUCTURAL FRAME= 0 HR
BEARING WALLS - EXTERIOR= 0 HR
BEARING WALLS  - INTERIOR= 0 HR
NONBEARING WALLS AND PARTITIONS, EXTERIOR= 0 HR
NONBEARING WALLS AND PARTITIONS, INTERIOR= 0 HR
FLOOR CONSTRUCTION= 0 HR
ROOF CONSTRUCTION= 0 HR
FIRE PROTECTION SYSTEMS - IBC CHAPTER 9
FIRE EXSTINGUISHERS FOR CLASS A (TABLE 906.3(1) ORDINARY HAZARD OCCUPANCY
MINIMUM RATED SINGLE EXTINGUISHER 2-A
MAXIMUM FLOOR AREA PER UNIT OF A 3,000 SF
MAXIMUM FLOOR AREA FOR EXTINGUISHER 11,250 SF
MAXIMUM DISTANCE OF TRAVEL 75 FT
FIRE RATINGS & SEPARATION DISTANCE: IBC TABLE 602
FIRE SEPARATION DISTANCE RATING
X < 5 1 HR
5 <= X < 10 1 HR
10 <= X < 30 0 HR
X >= 30 0 HR
MAX. AREA OF EXTERIOR WALL OPENINGS: IBC TABLE 705.8
FIRE SEPARATION DISTANCE RATING ALLOWABLE AREA
30 OR GREATER: UNPROTECTED, NONSPRINKLERED (UP, NS) NO LIMIT
UNPROTECTED, SPRINKLERED (UP, S) NO LIMIT
PROTECTED (P) NO LIMIT
MAIN BUILDING:
BUSINESS, MOST RESTRICTIVE
RESTROOM BUILDING:
BUSINESS, MOST RESTRICTIVE
REC LOUNGE:
BUSINESS, MOST RESTRICTIVE
1 1
3 6 4 4
ALLOWABLE BUILDING HEIGHT ABOVE GRADE (IBC TABLE 504.3) = 40 FT
TOTAL BUILDING HEIGHT= 29'-4"
ALLOWABLE NUMBER OF STORIES ABOVE GRADE, MOST RESTRICTIVE (IBC TABLE 504.4) = 2 STORIES
STORIES ABOVE GRADE PLANE = 1 STORY
ALLOWABLE AREA, MOST RESTRICTIVE (IBC TABLE 506.2) = 18,000 SF
BUILDING: ALLOWABLE: ACTUAL:
MAIN BUILDING: 9,000 GSF 7,807 GSF
(NEW CONSTRUCTION)
RESTROOM BUILDING 9,000 GSF 296 GSF
(NEW CONSTRUCTION)
BUILDING HEIGHTS & AREAS - IBC CHAPTER 5 
POOL AREAS
WATER CLOSETS LAVATORIES SHOWERS
MALE
1
FEMALE MALE FEMALE
N/A MALE: 2  FEMALE: 2
3 2
AREA (SF), OCCUPANTS: 
LAP POOL: 4654 SF, 94 OCC
LEISURE POOL : 4314 SF, 87 OCC
SPLASH PAD: 1406 SF, 29 OCC
TOTAL: 8968 SF, 210 OCC 2
PER ISPSC 2018, FOR POOL AREAS ABOVE 7500 SF, FOR EVERY 7500 SF:
WATER CLOSETS: 0.7 X MALE, 2 X FEMALE
URINALS: 1 X MALE
LAVATORIES: 0.85 X MALE, 1 X FEMALE
SHOWER: 1 X MALE, 1 X FEMALE
DRINKING FOUNTAINS
DRINKING FOUNTAINS
DRINKING FOUNTAINS
WATER CLOSETS LAVATORIES OTHER
MALE
1
FEMALE MALE FEMALE
1
1 1 1
ASSEMBLY
OCCUPANTS: 26 (OUTDOOR PATIO)
RESTROOM BUILDING:
DRINKING FOUNTAINS
WATER CLOSETS LAVATORIES OTHER
MALE
1
FEMALE MALE FEMALE
1
1 1 1
TOTAL FIXTURES REQUIRED
FIXTURES PROVIDED
2 2
2
1 1 1 1
DRINKING FOUNTAINS
URINALS
MALE
2
FEMALE
N/A
N/A
N/A
N/A
WATER CLOSETS: MALE - 1 PER 75; FEMALE - 1 PER 75 (FOOTNOTE: The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required.)
LAVATORIES: 1 PER 200, BOTH MALE AND FEMALE
DRINKING FOUNTAINS: 1 PER 500
OTHER: 1 SERVICE SINK
3
RECREATION
LOUNGE
127
77.60 SF
BUSINESS
1
17'-5" DE
PROJECT
NORTH
TRUE
NORTH RELEASED FOR CONSTRUCTION
THE LINE SHOWN ABOVE IS  EXACTLY ONE 
INCH LONG  AT THIS SHEETS ORIGINAL PAGE 
SIZE
THE  SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE 
LETTERS, IF PRINTED CORRECTLY
M CYK
Proj #: Reviewed By:
11/24/2025 5:05:24
PM
Autodesk Docs://Smyrna AquaticsGymFamilyLearningLibrary/Smyrna Aquatics Gym Family Learning Library.rvt
.
G00.20
LIFE SAFETY PLAN
22.0001924.000
PROJECT ADDRESS:
3530 KINGS SPRINGS RD SE
SMYRNA, GA 30080
TOLLESON PARK AQUATICS CENTER
.
CIVIL
200 COBB PARKWAY NORTH
STRUCTURAL
3411 PIERCE DRIVE
MEP
5064 ROSWELL ROAD
CROY ENGINEERING, LLC.
SHEAR STRUCTURAL
SAVANT ENGINEERING, LLC.
MARIETTA, GA 30062
CHAMBLEE, GA 30341
SANDY SPRINGS, GA 30342
770.971.5407
678.664.8051
770.319.7400
FOOD SERVICES
3103 MEDLOCK BRIDGE
CAMACHO
NORCROSS, GA 30071
770.246.2751
5200 Avalon Boulevard
Alpharetta, GA  30009
WWW.NELSONWORLDWIDE.COM
Phone: (770) 209-9393
Nelco Architecture, Inc.
1/8" = 1'-0"G00.20
1 MAIN BUILDING - CODE COMPLIANCE PLAN
LIFE SAFETY- OCCUPANCY- LEVEL 1
MAIN BUILDING
(NFPA101) ACCESORY STORAGE AREAS MECHANICAL EQUIPMENT ROOM
172.51 SF 300.00 SF 1
(NFPA101) ASSEMBLY - NO FIXED SEATS - UNCONCENTRATED
744.88 SF 15.00 SF 50
(NFPA101) BUSINESS AREAS
1451.03 SF 150.00 SF 11
(NFPA101) HIGH HAZARD GROUP H2
88.31 SF 500.00 SF 1
(NFPA101) UTILITY
1581.53 SF 500.00 SF 4
RECREATION LOUNGE
(IBC2018) BUSINESS AREAS
77.60 SF 150.00 SF 1
4115.87 SF 68
1/8" = 1'-0"G00.20
3 RESTROOM BUILDING - CODE COMPLIANCE PLAN
1/8" = 1'-0"G00.20
2 REC LOUNGE - CODE COMPLIANCE PLAN
1
1
Issue: No: Date:
DESIGN DEVELOPMENT 08-13-2025
PERMIT SET 09-30-2025
ISSUED FOR BID 1 10-16-2025
ADDENDUM #1 2 10-24-2025
PERMIT COMMENTS & CLARIFICATIONS 3 11-21-2025
2
.
.
.
.
RFI 28