Reeves Young
45 Peachtree Industrial Blvd
Sugar Hill, Georgia 30518
P: (770) 271-1159
Project: 25122- - Tolleson Park Aquatics Center
3530 King Springs Rd
Smyrna, Georgia 30080
CHANGE EVENT #024 - RFI #016 (Revision 1): Curtainwall Head Attachment - Envelope Coordination
Meeting
Origin: RFI #16 (Revision 1): Curtainwall Head Attachment - Envelope
Coordination Meeting
Date Created: 6/4/2026 Created By: Brent Newman
Status: Pending Scope: TBD
Type: Allowance Change Reason: Acceleration
Description: The Contract Documents are hereby amended to include the additional Work resulting from the design changes and modifications contained within the RFI #016-1 response as
issued by NELSON on 5/22/2026. The Work indicated by this RFI is outside of the current scope of the Work and constitutes a change. This CE is created for added blocking
and cladding to terminate storefront/curtainwall to stacked stone veneer. This CE also includes scope from storefront shop drawing identifying an additional beauty bead of
caulking outside of dry line assembly to provide finished condition between storefront and cladding. Also included is waterproofing of blocking and the cutting of jambs 3" back
on each side. CE originates from 5/7 Envelope Coordination Meeting, in which Subcontractors gathered to discuss finish detail discrepancies for the building(s). RY then
presented discrepancies in the 5/13 Envelope Coordination Meeting (with CROY , NELSON, and RY), in which the solution presented by NELSON in RFI #16-1 was confirmed.
This change is necessary in order to get clean finish from stone veneer to storefront/curtainwall. The RFI response consists of zero (0) new / revised drawings and includes the
additional Work described below: 
 
• Qty 75 lengths of "L" shape cladding
• Qty 50 lengths of "flat" cladding
• MATERIAL ONLY Fluid Applied Air/Water Barrier
• Cutting jambs 3" back ea side
• 2x8 PT Blocking
• 1,700 LF Beauty Bead
 
***NOTE: Previously presented as PCO #019.***
 
Contract Documents:
1. Amended to incorporate the Work modifications identified below. 
The Work:
1. As described above.
   
Contract Time: 
1. N/A
Contract Sum: 
1. Per breakdown below. 
Reeves Young Page 1 of 3 Printed on: 7/17/2026 at 02:46PM EDT