25122--Tolleson-Park-Aquatics-Center-002-PCCO-#002-July-2026_CroySigned
Open official source ↗ · Source page 52
POOLEQUIPMENT121CHEMICALS122 PANTRY104MEP103MULTIPURPOSE105 OFFICE120LIFEGUARDBREAK119CONCESSIONS102 ADMIN101 CONC. STOR112STORAGE106 OFFICE118 JAN113MOTHER115WOMEN117MEN114FAM RR116 PIT ROOM157 PH BUFFERROOM124 IT139RR140JAN143RR150 PIT ROOM157ELEC. CLOSET125S1-175CDS1-175CD2DTV TV TV TVTVTV2D2D1D1D F.2 F.1 E.2E.1 1D1D1DTVTVTVTV 1T-04 GENERAL NOTES:A.ALL INTERIOR CONDUIT PATHWAYS SHALL HAVE NO SINGLE BEND GREATER THAN 90°, ANAGGREGATE OF BENDS IN EXCESS OF 180 °, OR A CONTINUOUS SECTION LONGER THAN100' BETWEEN PULLING POINTS. PROVIDE PULL BOXES WHERE REQUIRED.B.ALL SLAB AND CMU BLOCK WALL PENETRATIONS TO BE FIREPROOFED AND SEALED.C.ALL SECURITY AND LOW VOLTAGE POWER CABLES TO BE ROUTED DIRECT TO EQUIPMENTROOMS WITHOUT SPLICES. NO JUNCTION OF SPLICES IN CABLES ARE ACCEPTABLE.D.COORDINATE EXACT LOCATION AND ORIENTATION OF VOICE AND DATA OUTLETS WITHPOWER RECEPTACLES. CONTRACTOR TO MOUNT OUTLET ADJACENT TO POWERRECEPTACLE AND MATCH POWER RECEPTACLE ORIENTATION.E.ALL SECURITY AND LOW VOLTAGE POWER CABLES TO BE PLENUM RATED. FOR ALLTELECOM INFRASTRUCTURE SYSTEMS PROVIDE EMT RACEWAY FROM TELECOM BACKBOXTO ACCESSIBLE CEILING SPACE AND PROVIDE J-HOOK SUPPORT TO TELECOM ROOM. J-HOOKSTO BE INSTALLED ON 4'0" TO 5'0" CENTERS. CABLES ARE NOT PERMITTED TO LAYUNSUPPORTED ACROSS CEILING TILES.F.IN OPEN CEILING & IN CEILING SPACE THAT ARE NOT ACCESSIBLE, ALL SIGNAL AND LOWVOLTAGE POWER CABLE TO BE ROUTED IN EMT CONDUIT. MINIMUM SIZE SHALL BE 3/4".SIZE PER NEC 40% FILL REQUIREMENT.G.ALL CABLE ROUTING TO BE CONCEALED IN PUBLIC AREAS. ALL CABLES TO BE NON-VISIBLETO PUBLIC.H.CONTRACTOR SHALL PROVIDE AND INSTALL BUSHINGS AT ALL EXPOSED CONDUIT ENDS.I.AT ALL EXTERIOR CAMERA LOCATIONS, CONTRACTOR TO PROVIDE AND INSTALL SURGESUPPRESSION DEVICES TYPICAL TO DITEK DTK-MRJPOE AT CAMERA LOCATION AND DITEKRACK MOUNT DTK-RM12POE SURGE PROTECTOR AT ASSOCIATED TELECOM CLOSET.J.ALL CAMERA LOCATIONS SHALL BE FIELD COORDINATED TO PROVIDE CLEAR FIELD OFVIEW.K.ALL WIRELESS ACCESS POINTS SHALL BE COORDINATED WITH OWNER AND WAP VENDORPROVIDED HEAT MAPPING PRIOR TO INSTALLATION.L.ALL LOW VOLTAGE CABLING IN PARKING LOT SHALL BE ROUTED IN EMT CONDUITSBURIED IN BURIAL RATED ELECTRICAL CONDUITS.MOUNT TV OUTLET ADJACENT TO POWER RECEPTACLE. COORDINATE EXACT LOCATIONOF DATA OUTLET WITH ARCHITECTURAL ELEVATIONS.COORDINATE FLOORBOX LOCATION AND REQUIREMENTS WITH AV/ELECTRICALDRAWINGS.KEY NOTES:12 PROJECTNORTHSHEET NO.: PROJECT NO.:SCALE:SHEET TITLE:DATE: NO.:DATE:REVISION: DRAWN BY: 654321 7 Place Services, Inc.201 Gateway DriveCanton, GA 30115office: 678-880-4777 3/18/26CADGIRL 4/15/26TPAC STC Drawings.dwgT-03STRUCTUREDCABLING PLAN1/8"=1'=0"TBD TOLLESON PARK AQUATICS CENTER3530 KINGS SPRINGS ROAD SE SMYRNA, GA 30080TELECOMMUNICATIONS SCALE:1STRUCTURED CABLING FLOOR PLAN1/8"=1'-0" SCALE:2REC LOUNGE1/8"=1'-0" 2 data 2 data 2 data 2 data 1 data 2 data, dry contact to fire alarm panel turnstyles 2 data coordinate network needs with mechanical/pool equipment vendor 1 data 2 data 2 data 2 data keep data no device single gang face stone single gang face stone single gang face stone single gang face stone