GENERAL NOTES:A.ALL INTERIOR CONDUIT PATHWAYS SHALL HAVE NO SINGLE BEND GREATER THAN 90°, ANAGGREGATE OF BENDS IN EXCESS OF 180 °, OR A CONTINUOUS SECTION LONGER THAN100' BETWEEN PULLING POINTS. PROVIDE PULL BOXES WHERE REQUIRED.B.ALL SLAB AND CMU BLOCK WALL PENETRATIONS TO BE FIREPROOFED AND SEALED.C.ALL SECURITY AND LOW VOLTAGE POWER CABLES TO BE ROUTED DIRECT TO EQUIPMENTROOMS WITHOUT SPLICES. NO JUNCTION OF SPLICES IN CABLES ARE ACCEPTABLE.D.COORDINATE EXACT LOCATION AND ORIENTATION OF VOICE AND DATA OUTLETS WITHPOWER RECEPTACLES. CONTRACTOR TO MOUNT OUTLET ADJACENT TO POWERRECEPTACLE AND MATCH POWER RECEPTACLE ORIENTATION.E.ALL SECURITY AND LOW VOLTAGE POWER CABLES TO BE PLENUM RATED. FOR ALLTELECOM INFRASTRUCTURE SYSTEMS PROVIDE EMT RACEWAY FROM TELECOM BACKBOXTO ACCESSIBLE CEILING SPACE AND PROVIDE J-HOOK SUPPORT TO TELECOM ROOM. J-HOOKSTO BE INSTALLED ON 4'0" TO 5'0" CENTERS. CABLES ARE NOT PERMITTED TO LAYUNSUPPORTED ACROSS CEILING TILES.F.IN OPEN CEILING & IN CEILING SPACE THAT ARE NOT ACCESSIBLE, ALL SIGNAL AND LOWVOLTAGE POWER CABLE TO BE ROUTED IN EMT CONDUIT. MINIMUM SIZE SHALL BE 3/4".SIZE PER NEC 40% FILL REQUIREMENT.G.ALL CABLE ROUTING TO BE CONCEALED IN PUBLIC AREAS. ALL CABLES TO BE NON-VISIBLETO PUBLIC.H.CONTRACTOR SHALL PROVIDE AND INSTALL BUSHINGS AT ALL EXPOSED CONDUIT ENDS.I.AT ALL EXTERIOR CAMERA LOCATIONS, CONTRACTOR TO PROVIDE AND INSTALL SURGESUPPRESSION DEVICES TYPICAL TO DITEK DTK-MRJPOE AT CAMERA LOCATION AND DITEKRACK MOUNT DTK-RM12POE SURGE PROTECTOR AT ASSOCIATED TELECOM CLOSET.J.ALL CAMERA LOCATIONS SHALL BE FIELD COORDINATED TO PROVIDE CLEAR FIELD OFVIEW.K.ALL WIRELESS ACCESS POINTS SHALL BE COORDINATED WITH OWNER AND WAP VENDORPROVIDED HEAT MAPPING PRIOR TO INSTALLATION.L.ALL LOW VOLTAGE CABLING IN PARKING STRUCTURE SHALL BE ROUTED IN EMT CONDUITSTIGHT TO CEILING AN SHALL BE PARALLEL TO ELECTRICAL CONDUITS. CONDUITS SHALLNOT BE ROUTED BELOW THE PARKING DECK CLEARANCE HEIGHT.CONTRACTOR TO INTEGRATE REQUEST-TO-EXIT SIGNAL FROM ELECTRIC DOOR HARDWAREAND DOOR POSITION SWITCH INTO ACCESS CONTROL SYSTEM. REQUEST-TO-EXIT SIGNALSHALL SHUNT DOOR ALARM. TYPICAL ALL DOORS.KEY NOTES:12ELECTRICAL CONTRACTOR TO PROVIDE DEDICATED 120 VAC , 20A,POWER RECEPTACLES AT 60" A.F.F. COORDINATE EXACTPLACEMENT WITH EQUIPMENT LOCATION.WIRE LEGENDIDDESCRIPTIONWIRE TYPEAACCESS CONTROL COMPOSITE CABLE - READER, LOCK, REX, DOOR SWITCHGENESIS 31961002BCATEGORY 6 DATA CABLE, CMP, BLUE (CCTV)PROVIDED BY TELECOM POOLEQUIPMENT121CHEMICALS122 PANTRY104MEP103MULTIPURPOSE105 OFFICE120 LIFEGUARDBREAK119CONCESSIONS102 ADMIN101CONC. STOR112STORAGE106 OFFICE118 JAN113MOTHER115WOMEN117MEN114FAM RR116 PIT ROOM157 PH BUFFERROOM124 IT139 RR140JAN143RR150 PIT ROOM157 ELEC. CLOSET125 T IT139 NVRACPPS 2 22 CRELCCRCR CRCR CRCRCRCR CR CR CR CRCRCRCRCELCEL CEL CELC CELCELCEL CEL CEL CEL CEL CELCELC CRCEL CEL 122124 125 126118120120A119117114113 116115 119B 101 102104105105A 105B 106108109110101A102A111112103 121 119A D-105BIDF 139 C-1.01IDF 139 C-1.02IDF 139 C-1.03IDF 139 10A,10B,1C 1A 1B3A,1B5A,1B11A3B 1B 1A2A4A,1B1A 1A,1B1B1A 5A,1B6A,2B5A,2B2A,1B1A D-105AIDF 139D-105IDF 139D-102IDF 139 D-104IDF 139 D-101IDF 139D-102AIDF 139 D-111IDF 139D-101AIDF 139 D-113IDF 139 D-119IDF 139 D-119AIDF 139D-118IDF 139D-120IDF 139 D-119BIDF 139 D-124IDF 139 D-111IDF 139 PROJECTNORTHSHEET NO.: PROJECT NO.:SCALE:SHEET TITLE:DATE: NO.:DATE:REVISION: DRAWN BY: 654321 7 Place Services, Inc.201 Gateway DriveCanton, GA 30115office: 678-880-4777 3/18/26CADGIRL 4/15/26TPAC CCTV ACCESS Drawings.dwgSEC-03SECURITY SYSTEMSFLOOR PLAN1/8"=1'-0"TBD TOLLESON PARK AQUATICS CENTER3530 KINGS SPRINGS ROAD SE SMYRNA, GA 30080CCTV AND ACCESS CONTROL SYSTEMS SCALE:1SECURITY SYSTEMS FLOOR PLAN1/8"=1'-0" CAM 180 degree CAM CAM CAM CAM Fisheye Fisheye Fisheye Fisheye (4) sensor CAM CAM (4) sensor CAM Fisheye check for corrosive lense CAM Fisheye single gang face stone single gang face stone single gang face stone single gang face stone single gang face stone