25122--Tolleson-Park-Aquatics-Center-002-PCCO-#002-July-2026_CroySigned
Open official source ↗ · Source page 26
FLOW IF THE HEATER IS U SIN G A DEDIC ATED AIR IN TAKE, A R EAR OR SIDE OPT ION MU ST BE SELECT ED. TH ESE WILL EXPAN D T HE FOO TPR INT OF TH E H EATER . IF T HE HEATER S ARE STACKED, THE T OP HEATER MUST USE T HE REAR CON NEC TION WHILE TH E LOWER C AN USE EITHER. AIR IN TAKES TO BE CO ORD INATED W ITH TH E MECH AN ICAL ENGINEER AND CO NSIDER ED WIT HIN TH E MECH ANICAL R OOM FO OTPRIN T. REAR SID E 6 5 5 4 2 1. 5 6 5 SUCT ION WASTE R ETUR N SUCT ION WASTE R ETUR N SUCT ION WASTE R ETUR N 6 5 6 5 6 5 TO POOL FROM PUMP BACKWASH 6 5 TO POOL FROM PUMPBACKWASH PP1 PP2 PP3 PP4 PP5 PP6 PP7 1A 1B 2B 3B CF6 F3 F3 F3 F1 F2 1C 2C 2C 2C 3C 3C 4A 5A 5C 5B 5F H1 L1 L2 L3 1E3E 3D 2D 1D 2E 2A 3A CF5 CF4 5D CF1 CF2 CF3 U1 U1 LAZY RIVER DRIVE LAZY RIVER DRIVE SPRAY PAD RECIRCULATION SPRAY PAD FEATURES LEISURE POOL RECIRCULATION LAP POOL RECIRCULATION ACID ROOM - pH CONTROL CHLORINE ROOM BACKWASH PIT SPRAY PAD FILTRATION SYSTEM LEISURE & RIVER FILTRATION SYSTEM - STACKED FILTERS LAP POOL FILTRATION SYSTEM - STACKED FILTERS LAP POOL CHEMICAL CONTROLLER LEISURE POOL CHEMICAL CONTROLLER SPRAY PAD CHEMICAL CONTROLLER WATER LEVEL CONTROLLERS POOL PUMP VFD'S 43'-0" X 12'-0" X 5'-0" DEEP PUMP PIT WATERSLIDE 10'-0" 10'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 10'-0" 10'-0" 9'-0" 9'-0" 8'-0" 8'-0" 9'-0" 8'-0" 8'-0" 7'-6" 7'-6" 9'-0" 9'-0" 9'-0" A A 1 9 102 3 4 5 6 7 13 14 15 16 A.1 A.1 11 12 B B B.1 B.1 CHEMICALS 122 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 12' - 0" 4' - 0" 16' - 0" 16' - 0" 20' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" MULTIPURPOSE 105 6' - 1"14' - 10 1/2"5' - 5 1/2" STORAGE 106 JAN 110 RR 108 MEP 103 IT 111 CONC. STOR 112 RR 109 CONCESSIONS 102 LIFEGUARD BREAK 119 ADMIN 101 CORRIDOR 107 PANTRY 104 4" 34' - 7 5/32" 8 27/32" 4" ROOF OVERHANG, TYP 2' - 6" ______________________ 3 A04.01 ______________________ 2 A04.01 ______________________ 1 A04.01 ______________________ 4 A04.01 MOTHER 115 JAN 113 FAM RR 116 MEN'S LOCKER RM 114 WOMEN'S LOCKER RM 117 RECESSED 85" TV OPEN STORAGE/SHELVING OUTDOOR PATIO 000 OFFICE 118 OFFICE 120 8 3 A04.02 _____________________ I04.00 1 A04.02 _____________________ PIT ROOM 123 3 A09.01 _____________________ 4 A09.01 _____________________ ELEC. CLOSET 125 PH BUFFER ROOM 124 5 A04.02 _____________________5 A04.02 _____________________ 2 A09.01 _____________________ 122 124 125 122A 118 120 120A 119 113 119B 102 104 105 106 108 109 110 101A 102A 111 112 103 121 119A CLOSET 120A xH12 H6 H8 3 xH12 xH12 H6 H6 H6 1 Maa3 Maa3 H6 H6 H6 xH12 xH12 Maa6 Mbb3 2 Mbb8 2 Mbb6 2 Mbb6 2Mbb3 2 ________________________________1 A07.00 ________________________________2 A07.00 A04.024 2 Ma3 Ma6 910 I04.00 12 I04.00 3 I04.005 4 B.2 B.2 ROOF ACCESS 132 CW-7 CW-7 CW-9 CW-7 CW-6 CW-4 CW-3 CW-2 CW-1 CW-11 CW-5 132 ________________________________ 6 A14.00 A14.00 7 DSDSDS DS DS 2' - 8" 3' - 0 1/2" 5' - 10 1/4" 5' - 6 1/2" 36' - 7 1/4" 1' - 2 1/2" 7" 9' - 10 1/2" 4' - 5 1/4" 9' - 11" 3' - 1 1/2" 22' - 10" 1' - 3" 27' - 5 1/4" 19' - 2 3/4" 4' - 10" 9' - 6 1/2" 11' - 11" 23' - 9 1/2" 2' - 0 3/4" 5' - 1" 5' - 1" ROOF OVERHANG, TYP 6' - 10" 6' - 0" 4' - 5 1/2" 12' - 10" 22' - 6 3/8" 2' - 4" 11' - 0" 17' - 4" 10' - 9 1/2" 5' - 6" 2' - 8" 3' - 0 1/2" 9' - 2 1/2" A.2 B.3 9' - 3" 4' - 10" 8' - 0 1/2" 7' - 10 1/2" 5' - 6 1/2" 20' - 8 1/2" 40' - 7" 6' - 2" 15' - 7" 3' - 7 3/4" 3' - 9 1/2" 12' - 3" 8' - 7 3/4" 2' - 0" 11' - 7" 2' - 0" 9' - 4" 11' - 3 3/4" 4" 4" 10" 4" 2' - 8" 5' - 8" 6' - 0" 8' - 0" 8' - 5" 4' - 7" 16' - 1" SUSPENDED MONITOR ABOVE W/ HEAVY DUTY POLE CEILING MOUNTING KIT, TYP. 36' - 0" 10' - 7 1/2" 3' - 3 1/2" 8' - 4 1/2" 8' - 3 1/2" W01 W01 W01 W01 CW-8 CW-10 CW-12 SF-21 ________________________________4 A07.01 ________________________________ 7 A07.01 ________________________________ 3 A07.01 ________________________________ 6 A07.01 ________________________________5 A07.01 117 114 CW-8 101 11 36' - 0" 3' - 6" 3' - 6" 228' - 0" 6' - 1 3/4" 6' - 8" 16' - 6" 10' - 6" 4' - 11 1/2" SPRINKLER RISER ROOM 131 EXTERIOR GATE - SEE CIVIL FOR INFORMATION ________________________________ 9 A07.01 EXTERIOR FENCE POTENTIALLY BEING ADDED HERE - SEE CIVIL FOR INFORMATION ________________________________ 10 A07.01 ________________________________ 11 A07.01 131 TA-12 EQ-03 EQ-02 EQ-04 105A 105B 1' - 9 1/2" ________________________________ 13 A07.01 A07.00 3 BREEZEWAY SPACE OVERHEAD WH. SEE STRUCT. EXTERIOR GATE, SEE CIVIL 116 115 ALVARADO MFG. TURNSTILE SYSTEM INGRADE LIGHT FIXTURE. SEE ELECTRICAL, TYP. INGRADE LIGHT FIXTURE (L18). SEE ELECTRICAL, TYP. Ma2 16' - 3" 1' - 11" 19' - 10" Ma2 Ma2 Ma2 Ma2 H6 A07.00 3 W-2 L18 INGRADE LIGHT FIXTURE. SEE ELECTRICAL, TYP. L18L18L18L18 3 3 3 EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ2' - 8"1' - 5" EQ EQ EQ EQ 3' - 6"EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 2' - 0" 3' - 8" 2' - 0" L20 L20 L20 1' - 0" 1' - 0" 1' - 0" L20 L20 L20L20 3 3 3 3 3 3 3 3333 3 3 6 A09.02 _____________________ CONTRACTOR TO PROVIDE FLUID APPLIED WATERPROOFING ON ALL 4 INTERIOR WALL FACES AND BOTTOM OF BACKWASH BASIN. 3 C8 A 1 9 102 3 4 5 6 7 13 14 15 16 A.1 11 12 B B.1 8 4' - 2" 4' - 0" 4' - 3 1/2" 4' - 0" 92' - 3 1/2" 4' - 0" 7' - 8" 3' - 4" 1' - 6" 14' - 6" 1' - 6" 6' - 6 1/2" 3' - 1 1/2" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 12' - 0" 4' - 0" 16' - 0" 16' - 0" 20' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 7 1/2" 39' - 6 1/2" 7' - 2 1/2" 10' - 0" 17' - 4 1/2" 9' - 1 1/2" 15' - 7 1/2" 8' - 7 1/2" 51' - 0" 3' - 4" 5' - 1" 3' - 3" 1' - 4" 14' - 8" 1' - 5" 11' - 6 1/2" 7 1/2" 4" 5 1/2" 5 1/2" 4" 4" 7 1/2" 7 1/2" 1' - 4 1/2" 1/2" 4' - 9 1/2" 1' - 2 1/2" 23' - 4" 1' - 2 1/2" 4' - 9 1/2"1/2" 5' - 10" 1' - 5 1/2" 3' - 1 1/2" SLAB NOT PART OF BUILDING PACKAGE SCOPE - REFER TO CIVIL DRAWINGS FOR MORE INFO. SLAB NOT PART OF BUILDING PACKAGE SCOPE - REFER TO CIVIL DRAWINGS FOR MORE INFO. 3 1/2" 3' - 0 1/2" 4" B.2 A.2 B.3 CONTRACTOR TO COORDINATE LEVEL SURFACE FOR CMU WALL LOCATIONS - TYP. 1:12 1:121:12 -5' - 0" -5' - 0" -5' - 0" -5' - 0" 2' - 8 1/2"3' - 1 1/2" 3' - 5 1/2" 8' - 2 1/2" 5' - 4" 5' - 9" SLAB NOT PART OF BUILDING PACKAGE SCOPE - REFER TO CIVIL DRAWINGS FOR MORE INFO. 1:121:12 1:121:12 TYP.TYP. TYP. TYP. 9' - 1 3/4" 5' - 6 1/4" 21' - 5 1/2" 7' - 8 1/4" -1"5" 5" 5" 5" 4' - 0 1/2" 7' - 3" 4"3' - 4"1' - 9"3' - 3" 1' - 3" 3' - 4" 6' - 5" 3' - 4" 1' - 3" 4"3' - 4"1' - 9" 3' - 3" 10' - 11" 5' - 11" 2' - 4" 5' - 8 1/2" 3' - 7 1/2" 5' - 2" 4' - 6 1/2" 8' - 11 1/2" 9' - 10 1/2" 3' - 9 1/2" 9' - 9" 1' - 3" 3' - 9 1/2" 4' - 3" 2' - 6" 5' - 9 1/2" 6' - 11" 6' - 4" 6' - 5" 3' - 4" 1' - 3" 3' - 4" 1' - 4 1/2" 12' - 4 1/2" 5' - 6 1/2" 12' - 4 1/2" 12' - 10" 3' - 10" 7' - 5 1/2" 8 1/2" 5' - 7" 7' - 5" 2' - 9" 3' - 10" 6' - 5" 3' - 0 1/2" 9' - 5 1/2" 6' - 5" 3' - 0 1/2" 4' - 0 1/2" 8' - 3 1/2" 5' - 10 1/2" 3' - 6 1/2" 1' - 10" 7' - 11" 5" 5" 5" 6" 4' - 6 1/2" 6' - 3" 5" -1/2" 7' - 6" 5" 7' - 6" -1/2" 7' - 1" 3 1/8" = 1'-0"A02.00 2 MAIN BUILDING - EDGE OF SLAB PLAN PROJECT NORTH TRUE NORTH RELEASED FOR CONSTRUCTION THE LINE SHOWN ABOVE IS EXACTLY ONE INCH LONG AT THIS SHEETS ORIGINAL PAGE SIZE THE SQUARES ABOVE ARE COLOR, WITH BLACK AND WHITE LETTERS, IF PRINTED CORRECTLY M CYK Proj #: Reviewed By: 11/24/2025 5:05:50 PM Autodesk Docs://Smyrna AquaticsGymFamilyLearningLibrary/Smyrna Aquatics Gym Family Learning Library.rvt . A02.00 MAIN BUILDING EOS & FLOOR PLAN 22.0001924.000 PROJECT ADDRESS: 3530 KINGS SPRINGS RD SE SMYRNA, GA 30080 TOLLESON PARK AQUATICS CENTER . CIVIL 200 COBB PARKWAY NORTH STRUCTURAL 3411 PIERCE DRIVE MEP 5064 ROSWELL ROAD CROY ENGINEERING, LLC. SHEAR STRUCTURAL SAVANT ENGINEERING, LLC. MARIETTA, GA 30062 CHAMBLEE, GA 30341 SANDY SPRINGS, GA 30342 770.971.5407 678.664.8051 770.319.7400 FOOD SERVICES 3103 MEDLOCK BRIDGE CAMACHO NORCROSS, GA 30071 770.246.2751 5200 Avalon Boulevard Alpharetta, GA 30009 WWW.NELSONWORLDWIDE.COM Phone: (770) 209-9393 Nelco Architecture, Inc. 1/8" = 1'-0"A02.00 1 MAIN BUILDING - FLOOR PLAN 1 1 1 1 1 1 1 1 1 1 2 2 2 2 Issue: No: Date: SCHEMATIC DESIGN 06-05-2025 DESIGN DEVELOPMENT 08-13-2025 PERMIT SET 09-30-2025 ISSUED FOR BID 1 10-16-2025 ADDENDUM #1 2 10-24-2025 PERMIT COMMENTS & CLARIFICATIONS 3 11-21-2025 2 2 2 22 2 2 2 222 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 . . . . L20 RFI 15 RFI 15 RFI 8 RFI 4 RY RFI Exhibit: